Resultado da pesquisa (4)

Termo utilizado na pesquisa frequência cardíaca

#1 - Prognostic value of coupling interval, prematurity index and heart rate variability in Boxer dogs

Abstract in English:

Boxer dogs with arrhythmogenic right ventricular cardiomyopathy (ARVC) can experience sudden cardiac death regardless of presence/absence of clinical signs. The aims of this retrospective study were two-fold: 1) to investigate the coupling interval (CI) and prematurity index (PI) of ventricular arrhythmias (VA), and the heart rate variability (HRV) in Boxers, and 2) to evaluate their impact on overall survival time. The first 24-hour Holter 36 client-owned Boxer dogs meeting inclusion/exclusion criteria were evaluated for the number, morphology, site of origin, complexity, CI and PI, of ventricular premature complexes (VPCs), and time domain HRV. The effect on survival was assessed, considering the presence/absence of ventricular tachycardia (VT), and syncope. All-cause mortality was considered as the end-point, with median survival times being obtained by Kaplan-Meier analyses and compared by log-rank test. Polymorphic VPCs were more common in symptomatic dogs than asymptomatic. VPCs in dogs with VT were less premature, due to the influence of heart rate on PI despite comparable CI. The PI and mean heart rate (HRme) were significantly different between VT and non-VT dogs but did not discriminate adequately between groups as standalone tests. Median survival time was shorter in Boxer dogs with VT (463 vs 1645 days, HR: 4.31, P=0.03). The HRV parameters, SDNN and SDANN, were both associated with prognosis. The CI and PI were not demonstrated to be prognostic surrogates in Boxer dogs with VA. HRme≥112bpm is 100% sensitive but only 46% specific for detecting VT in Boxers on the 24-hour Holter. Presence of VT, SDNN≤245ms, or SDANN≤134ms at the time of the first 24-hour Holter was associated with a shorter survival.

Abstract in Portuguese:

Cães da raça Boxer com cardiomiopatia arritmogênica do ventrículo direito (CAVD) podem apresentar morte súbita independentemente da presença/ausência de sinais clínicos. Os objetivos desse estudo retrospectivo foram: 1) investigar o intervalo de acoplamento (IA) e o índice de prematuridade (IP) das arritmias ventriculares e a variabilidade da frequência cardíaca (VFC) em Boxers, e 2) avaliar o impacto de tais características sob o tempo de sobrevida global. O primeiro Holter de 24 horas de 36 Boxers selecionados para os critérios de inclusão/exclusão foram avaliados para o número, morfologia, local de origem, complexidade, IA e IP dos complexos ventriculares prematuros (CVPs) e da VFC no domínio do tempo. O efeito na sobrevida foi avaliado, considerado a presença/ausência de taquicardia ventricular (TV), e síncope. O desfecho final foi a mortalidade global, com o tempo de sobrevida mediano sendo obtido pela análise de Kaplan-Meier e comparado pelo teste de log-rank. CVPs polimórficos foram mais comuns em cães sintomáticos. Os CVPs em Boxers com TV foram menos prematuros, devido à influência da frequência cardíaca (FC) sobre o IP, apesar de IA comparáveis. O IP e a FC média diferiram entre os cães com TV e os sem, mas não discriminam adequadamente os grupos como variáveis isoladas. A sobrevida global foi menor nos cães com TV (463 dias vs 1645 dias, HR=4,31, P=0,03). Os parâmetros da VFC, SDNN e SDANN, foram associados ao prognóstico. O IA e o IP não possuem valor prognóstico em Boxers com arritmias ventriculares. A FC média ≥112bpm é 100% sensível, mas apenas 46% específica para detectar Boxers com TV no Holter de 24 horas. A presença de TV, SDNN≤245ms, ou SDANN≤134ms no momento do primeiro Holter de 24 horas estão associados a menor sobrevida global no Boxer.


#2 - Maternal, fetal and neonatal heart rate and heart rate variability in Holstein cattle

Abstract in English:

The aim of this study was to describe the normal values for maternal, fetal and neonatal heart rate (HR) and heart rate variability (HRV) indexes in the time domain (standard deviation of beat-to-beat interval - SDNN; root mean square of successive beat-to-beat differences - RMSSD) and the frequency domain (low frequency - LF; high frequency - HF; relationship between low and high frequency - LF/HF) in 23 Holstein cows, 23 fetuses and 18 neonates during the perinatal period. HR and HRV were calculated by fetomaternal electrocardiography (ECG). Fetomaternal measurements were taken six times prepartum (between days 234 and 279 of pregnancy) and measurements were taken in neonates six times after calving (after birth and five times weekly). HR, time and frequency domain were analyzed. No significant changes in maternal, fetal beat-to-beat interval (RR interval) or HR were found. In maternal variables, SDNN decreased significantly from 38.08±2.6ms (day 14 before calving) to 23.7±2.5ms (day 1 after calving) (p<0.05), but the RMSSD did not change significantly. HR and RR interval of calf differed statistically from the day before delivery (163±7.5bpm; 381±24.2ms) to the day after calving (131±5bpm; 472±16.2ms). Time variables (SDNN and RMSSD) and the frequency-domain variables (LF and HF) were significantly different (p<0.05) between fetal and neonatal stages. Reductions in the values of SDNN and RMSSD can reflect a sympathetic dominance. After calving, the increase in HF and decrease in LF variables can indicate activation of the vagal nerve followed by heart and respiratory modulation.

Abstract in Portuguese:

O objetivo deste estudo foi descrever os valores normais para os índices de frequência cardíaca (FC) materna, fetal e neonatal e de variabilidade da frequência cardíaca (VFC) no domínio do tempo (desvio padrão do intervalo batimento a batimento, SDNN; raiz quadrada média de sucessivas diferenças de batimento a batimento, RMSSD) e do domínio da frequência (baixa frequência, LF; alta frequência, HF; relação entre baixa e alta frequência, LF/HF) em 23 vacas Holandesas, 23 fetos e 18 neonatos durante o período perinatal. A FC e a VFC foram calculadas por eletrocardiografia materno-fetal. As medidas materno‑fetais foram realizadas seis vezes antes do parto (entre os dias 234 e 279 de gestação) as medidas neonatais foram realizadas seis vezes após o parto (um dia após nascimento e semanalmente, durante cinco semanas). FC, e variáveis no domínio do tempo e de frequência foram analisadas. Não foram encontradas alterações significativas na FC e no intervalo de batimento para batimento (intervalo RR) materno e fetal. Nas variáveis ​​maternas, o SDNN diminuiu significativamente de 38,08±2,6ms (dia 14 antes do parto) para 23,7±2,5ms (dia 1 após o parto) (p<0,05), mas o RMSSD não alterou significativamente. A FC e o intervalo e RR do bezerro diferiram estatisticamente a partir de um dia antes do parto (163±7,5bpm, 381±24,2ms) até o dia seguinte ao parto (131±5bpm, 472±16,2ms). As variáveis ​​de tempo (SDNN e RMSSD) e as variáveis ​​de domínio de frequência (LF e HF) foram significativamente diferentes (p<0,05) entre os momentos fetal e neonatal. As reduções nos valores de SDNN e RMSSD podem refletir domínio simpático. Após o parto, o aumento da HF e a diminuição das variáveis ​​LF podem indicar a ativação do nervo vagal seguido de modulação cardíaca e respiratória.


#3 - Maternal, fetal and neonatal heart rate evaluation and its variability in the Paint Horse breed

Abstract in English:

The aim of this study were to describe the heart rate (HR) and indexes of maternal and fetal heart rate variability (HRV) in final period of pregnancy, as well as to describe the evolution of the development of autonomic nervous system during fetal and neonatal period. There were 20 animals in each category, whose maternal and fetal electrocardiographic examinations were performed at 15 and 7 days antepartum. Neonatal ECG it was evaluated at birth until the first 48 hours of life, and then once a week up to 35 days. There were significant differences in fetal heart rate (FHR) during this period, but the fetal HRV indexes have not changed. There were no significant differences in the rates of maternal HRV. The mean of fetal HR decreased significantly from 15 to seven antepartum days (95.6±11.4 bpm; 83.1±12.6, respectively), though the fetal HRV indexes have not decreased. The results of fetal and neonatal HRV in the present study, when compared to maternal indicate the parasympathetic dominance during fetal and neonatal sympathetic phase during to the third and/or fourth weeks of age, at which point begins the modulation of the two systems.

Abstract in Portuguese:

Os objetivos deste estudo foram descrever a frequência cardíaca (FC) e os índices de variabilidade da frequência cardíaca (VFC) materna e fetal no terço final da gestação, bem como descrever a evolução do desenvolvimento do sistema nervoso autônomo durante o período fetal e neonatal. Foram avaliados 20 animais de cada categoria, cujos exames eletrocardiográficos, maternos e fetais, foram realizados aos 15 e sete dias pré-parto. Quanto ao eletrocardiograma neonatal, os momentos avaliados foram ao nascimento até as primeiras 48 horas de vida, e posteriormente, uma vez por semana até os 35 dias de idade. Ocorreram diferenças significativas na frequência cardíaca fetal (FCF) no período avaliado, porém os índices de VFC fetais não se alteraram. Não foram encontradas diferenças significativas nos índices de VFC materna. A média da FCF diminuiu significativamente dos 15 para sete dias do pré-parto (95,6±11,4 bpm; 83,1±12,6, respectivamente), entretanto os índices de VFC fetal não diminuíram. Os resultados obtidos da VFC fetal e neonatal deste estudo, quando comparados aos maternos, indicaram predomínio parassimpático durante a fase fetal e, simpático durante a neonatal, até a terceira e/ou quarta semanas de idade, momento no qual se inicia o equilíbrio entre os dois sistemas.


#4 - QT interval in healthy dogs: which method of correcting the QT interval in dogs is appropriate for use in small animal clinics?, 34(5):469-472

Abstract in English:

ABSTRACT.- Oliveira M.S., Muzzi R.A.L., Muzzi L.A.L., Cherem M. & Mantovani M.M. 2014. QT interval in healthy dogs: which method of correcting the QT interval in dogs is most appropriate for use in small animal clinics? Pesquisa Veterinária Brasileira 34(5):469-472. Departamento de Medicina Veterinária, Universidade Federal de Lavras, Cx. Postal 3037, Lavras, MG 37200-000, Brazil. E-mail: ralmuzzi@dmv.ufla.br The electrocardiography (ECG) QT interval is influenced by fluctuations in heart rate (HR) what may lead to misinterpretation of its length. Considering that alterations in QT interval length reflect abnormalities of the ventricular repolarisation which predispose to occurrence of arrhythmias, this variable must be properly evaluated. The aim of this work is to determine which method of correcting the QT interval is the most appropriate for dogs regarding different ranges of normal HR (different breeds). Healthy adult dogs (n=130; German Shepherd, Boxer, Pit Bull Terrier, and Poodle) were submitted to ECG examination and QT intervals were determined in triplicates from the bipolar limb II lead and corrected for the effects of HR through the application of three published formulae involving quadratic, cubic or linear regression. The mean corrected QT values (QTc) obtained using the diverse formulae were significantly different (&#961;<0.05), while those derived according to the equation QTcV = QT + 0.087(1- RR) were the most consistent (linear regression). QTcV values were strongly correlated (r=0.83) with the QT interval and showed a coefficient of variation of 8.37% and a 95% confidence interval of 0.22-0.23 s. Owing to its simplicity and reliability, the QTcV was considered the most appropriate to be used for the correction of QT interval in dogs.

Abstract in Portuguese:

RESUMO.- Oliveira M.S., Muzzi R.A.L., Muzzi L.A.L., Cherem M. & Mantovani M.M. 2014. QT interval in healthy dogs: which method of correcting the QT interval in dogs is most appropriate for use in small animal clinics? [Intervalo QT em cães hígidos: qual método de correção para o intervalo QT é mais apropriado na clínica de pequenos animais?] Pesquisa Veterinária Brasileira 34(5):469-472. Departamento de Medicina Veterinária, Universidade Federal de Lavras, Cx. Postal 3037, Lavras, MG 37200-000, Brazil. E-mail: ralmuzzi@dmv.ufla.br O intervalo QT do eletrocardiograma (ECG) é influenciado por variações da frequência cardíaca (FC), o que pode levar a erros na interpretação de sua duração. Considerando que as alterações na duração do intervalo QT refletem anormalidades da repolarização ventricular, as quais predispõem a ocorrência de arritmias, esta variável deve ser devidamente avaliada. O objetivo deste trabalho foi determinar qual método de correção do intervalo QT é mais adequado para os cães, considerando-se diferentes intervalos de FC normais. Cães adultos saudáveis, de diferentes raças (n=130; Pastor Alemão, Boxer, Pit Bull Terrier e Poodle) foram submetidos ao exame eletrocardiográfico, no qual se determinaram os intervalos QT a partir da derivação bipolar II e foram corrigidos os efeitos da FC por meio da aplicação de três fórmulas, envolvendo regressão quadrática, cúbica ou linear. Os valores do QT corrigido (QTc) obtidos utilizando as diversas fórmulas foram significativamente diferentes (&#961;<0,05), sendo os derivados da equação QTcV = QT + 0,087 (1- RR), os mais consistentes (regressão linear). Valores de QTcV apresentaram correlação significativa e de alta magnitude (r=0,83) com o intervalo QT, baixo coeficiente de variação (8,37%) e intervalo de confiança de 95% de 0,22-0,23s. Devido à confiabilidade dos dados, o QTcV foi considerado o mais apropriado para ser utilizado para a correção do intervalo QT em cães, além de ser um método de fácil execução.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV